UV Air Sterilizer

Description

1 ) PKL PPC BK-Y-800

Mobile UV Air Sterilizer

Features

It can be used in Class II, Class III, Class IV hospital room, blood station, food and beverage factory, pharmaceutical factory, school, catering and other public places.

* Display indoor temperature.
* Timing function of UV lamp cumulative use.
* Adopt quick disassembly filter, easy to clean and maintain.
* Air volume status display, high/medium/low air volume adjustable.
* Built-in high brightness, long life, ozone – free, U – type UV lamp.
* The super-infrared receiving device can realize long-distance remote control and easy operation a any 45 degrees. A built-in hidden remote control is placed to prevent the remote from being lost.
* High quality mirror plate is used to enhance the radiation intensity of ultraviolet lamp and improve the sterilization efficiency. .

PPC BK-Y-800 Technical Data:

Model BK-Y-800
Circulating Air ≥800m3/h
Noise ≤50dB
O3 Residue ≤0.0074mg/m3
Applicable Room ≤60m3
Ultraviolet Leakage ≤5μw/cm2
Working Environment Temp.Range -10ºC~40ºC
Humidity ≤80%
Atmosphere Pressure 60KPa~106KPa
Consumption ≤350W
Power Supply AC110/220V±10%, 50/60Hz
External Size(W*D*H)mm 540*420*900
Packing Size(W*D*H)mm 580*490*90
Gross Weight(kg) 22.5
 
   

2) PKL PPC BK-G-1200

Floor Standing UV Air Sterilizer

Features

It can be used in Class II, Class III, Class IV hospital room, blood station, food and beverage factory, pharmaceutical factory, school, catering and other public places.

* Large LCD display.

* Timing function of UV lamp cumulative use.

* Three modes of operation: Automatic, Artificial, Timing.

* Built-in high brightness, long life, ozone – free, U – type UV lamp.

* Automatic fault alarm function: UV lamp tube, motor, negative ion, plasma and O3.

* Within 24 hours, four periods of disinfection can be set and memory function can be provided.

* Automatically detect and display the temperature and humidity of the disinfection space in real time.

* Single chip microcomputer control, stable and reliable. Touch panel operation, convenient for man-machine interaction.

* The super-infrared receiving device can realize long-distance remote control and easy operation at any 45 degrees.

  A built-in hidden remote control is placed to prevent the remote from being lost.

* Adopt the structure of bottom air inlet and top air outlet. The silent fan circulates the air to prevent the cold air from blowing directly to the user.

* High quality mirror plate is used to enhance the radiation intensity of ultraviolet lamp and improve the sterilization efficiency.

* Automatically detect and display indoor air quality. When the air pollution index exceeds the standard, it will automatically start up and purify.

PPC BK-G-1200 Technical Data

Model BK-G-1200
Circulating Air ≥1200m3/h
Noise ≤55dB
O3 Residue ≤0.0074mg/m3
Applicable Room ≤120m3
Ultraviolet Leakage ≤5μw/cm2
Working Environment Temp.Range -10ºC~40ºC
Humidity ≤80%
Atmosphere Pressure 60KPa~106KPa
Consumption ≤400W
Power Supply AC110/220V±10%, 50/60Hz
External Size(W*D*H)mm 532*330*1691
Packing Size(W*D*H)mm 585*380*1830
Gross Weight(kg) 55.6
 
   

3) PKL PPC BK-B-1000

Wall Mounted UV Air Sterilizer

Features

It can be used in Class II, Class III, Class IV hospital room, blood station, food and beverage factory, pharmaceutical factory, school, catering and other public places.

* Large LCD display.

* Timing function of UV lamp cumulative use.

* Three modes of operation: Automatic, Artificial, Timing.

* Built-in high brightness, long life, ozone – free, U – type UV lamp.

* Automatic fault alarm function: UV lamp tube, motor, negative ion, plasma and O3.

* Within 24 hours, four periods of disinfection can be set and memory function can be provided.

* Automatically detect and display the temperature and humidity of the disinfection space in real time.

* Single chip microcomputer control, stable and reliable. Touch panel operation, convenient for man-machine interaction.

* The super-infrared receiving device can realize long-distance remote control and easy operation at any 45 degrees.

  A built-in hidden remote control is placed to prevent the remote from being lost.

* Adopt the structure of bottom air inlet and top air outlet. The silent fan circulates the air to prevent the cold air from blowing directly to the user.

* High quality mirror plate is used to enhance the radiation intensity of ultraviolet lamp and improve the sterilization efficiency.

* Automatically detect and display indoor air quality. When the air pollution index exceeds the standard, it will automatically start up and purify.

PPC BK-B-1000 Technical Data

Model BK-B-1000
Circulating Air ≥1000m3/h
Noise ≤55dB
O3 Residue ≤0.0074mg/m3
Applicable Room ≤100m3
Ultraviolet Leakage ≤5μw/cm2
Working Environment Temp.Range -10ºC~40ºC
Humidity ≤80%
Atmosphere Pressure 60KPa~106KPa
Consumption ≤400W
Power Supply AC110/220V±10%, 50/60Hz
External Size(W*D*H)mm 1000*450*195
Packing Size(W*D*H)mm 1150*560*240
Gross Weight(kg) 33

 